Mostrar el registro sencillo del ítem

dc.creatorYoles Sirena, Noelia
dc.date2023-01-11
dc.date.accessioned2023-02-17T18:48:38Z
dc.date.available2023-02-17T18:48:38Z
dc.date.issued2022-12-13
dc.identifier.citationYoles Sirena, N. (2023). Análisis, diagnóstico y propuesta de manejo para los cuerpos de agua destinados al consumo humano de la Localidad de Herrera, Departamento Avellaneda, Santiago del Estero. (Tesis de posgrado). Universidad Nacional de Quilmes, Bernal, Argentina.es
dc.identifier.urihttp://ridaa.unq.edu.ar/handle/20.500.11807/3949
dc.descriptionFil: Yoles Sirena, Noelia. Universidad Nacional de Santiago del Estero. Facultad de Ciencias Forestales; Argentina.
dc.descriptionFil: Yoles Sirena, Noelia. Santiago del Estero. Dirección de Obras Sanitarias de Santiago del Estero; Argentina.
dc.description.abstractHoy en día, una de las problemáticas emergentes que afecta la calidad de los cuerpos de agua superficiales destinados para consumo humano, es la eutrofización. Considerada esta última, como un indicador ambiental de estado por el Banco Mundial, este fenómeno afecta directamente a nivel operacional y sanitario a las plantas potabilizadoras. Con la finalidad de medir la eutrofización, se determinó el Estado Trófico en las fuentes de abastecimiento de agua a la planta potabilizadora de la Localidad de Herrera, tomando muestras en el Río Salado y sus Represas de Almacenamiento, durante la primavera (período seco). En los puntos donde se tomaron las muestras, se midieron “in situ” parámetros físicos, obteniéndose como valores promedio: pH de 7-8,7; temperatura 23,66 °C; oxígeno disuelto 3-8 mg/l, conductividad eléctrica de 2000-7000 mS/m, siendo este último parámetro, el que manifestó valores superiores a lo normal. Luego, sobre cada muestra extraída, fueron analizados parámetros nutricionales (Nitratos y Fosfatos), observándose en todos los puntos de muestreo para el caso de los NO3-, concentraciones promedio en un rango de 21,36 a 13,72 mg/l, valores que superan lo máximo permitido en aguas superficiales dulces no contaminadas. En el caso del PO4-3, las concentraciones medidas oscilaron en valores promedio entre 0,65 mg/l y 1,27 mg/l, encontrándose dentro del rango óptimo. El parámetro biológico analizado en las muestras, fue la clorofila-a, la cual reflejó valores que abarcan un rango de 1,73 y 14,12 μg/l, estos valores son aceptables para sistemas acuáticos al ser inferiores a 50 μg/l, reflejan que estas fuentes de agua deberán ser tratadas mediante un sistema sofisticado de potabilización correspondiente a aguas nivel 2 (tratamiento de potabilización donde se consideren tendencias a un incremento de algas) como existe en la actualidad. A partir de este valor se pudo calcular el Estado Trófico, el cual mide indirectamente el estado de eutrofización de los cuerpos de agua. Este definió que el diagnóstico de los cuerpos de agua durante el periodo de estudio, era Mesotrófico (30<TSI≤60) para todos los puntos de muestreo. A través del estudio de los caracteres físicos, nutricionales y tróficos de los puntos de estudio, se pudo elevar un diagnóstico que permitió diseñar una propuesta de plan para el manejo integrado de los cuerpos de agua aledaños a la planta potabilizadora de la localidad de Herrera, para de esta forma prevenir y proteger a las fuentes de abastecimiento y reducir riesgos ecológicos en la cuenca.es
dc.description.abstractToday, one of the emerging problems that affects the quality of surface water bodies intended for human consumption is eutrophication. Considered the latter, as an environmental status indicator by the World Bank, this phenomenon directly affects the operational and sanitary level of the water treatment plants. In order to measure eutrophication, the Trophic Status was determined in the water supply sources to the water treatment plant in the Town of Herrera, taking samples from the Salado River and its Storage Dams, during the spring (dry period). Physical parameters were measured “in situ” at the points where the samples were taken, obtaining average values: pH 7-8.7, temperature 23.66 °C; dissolved oxygen 3-8 mg/l, electrical conductivity of 2000-7000 mS/cm, this last parameter being the one that showed values higher than normal. Then, on each extracted sample, nutritional parameters (Nitrates and Phosphates) were analyzed, observing in all the sampling points in the case of NO3-, average quantities in a range of 21,3 to 13,7 mg/l, values that exceed the maximum allowed in uncontaminated fresh surface water. In the case of PO4-3, the measured amounts ranged in average values between 0.65 mg/l and 1,27 mg/l, being within the optimal range. Chlorophyll-a was the biological parameter analyzed in the samples considered, the values obtained are intro the range of 1,73 and 14,12 μg/l. These values are acceptable for aquatic systems as they are less than 50 μg/l but that these water sources must be treated by means of a sophisticated purification system corresponding to level 2 water (purification treatment where tendencies to an increase in algae are considered) as it currently exists. From this value it was possible to calculate the Trophic State, which indirectly measures the state of eutrophication of the water bodies. This defined that the diagnosis of the water bodies during the study period was Mesotrophic (30<TSI≤60) for all sampling points. Through the study of the physical, nutritional and trophic characteristics of the study points,a diagnosis was made that allowed the design of a plan proposal for the integrated management of the water bodies surrounding the water treatment plant in the town of Herrera, to prevent and protect the sources of supply and reduce ecological risks in the basin.es
dc.formatapplication/pdfes
dc.format.extent78 p.es
dc.languagespaes
dc.publisherUniversidad Nacional de Quilmeses
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/es
dc.subjectAguaes
dc.subjectEutrofizaciónes
dc.subjectPlantas potabilizadorases
dc.subjectWateres
dc.subjectEutrophicationes
dc.subjectWater treatment plantses
dc.subjectEutrofizaçãoes
dc.subjectEstações de tratamento de águaes
dc.titleAnálisis, diagnóstico y propuesta de manejo para los cuerpos de agua destinados al consumo humano de la Localidad de Herrera, Departamento Avellaneda, Santiago del Esteroes
dc.typeinfo:ar-repo/semantics/tesis de maestríaes
unq.tesis.directorSimanauskas, Tristán
unq.tesis.codirectorTévez, Héctor Rodolfo
unq.tesis.calificacionAprobado-Sobresalientees
unq.tesis.tituloMaestría en Ambiente y Desarrollo Sustentablees
unq.tesis.juradoMarrochi, Natalia
unq.tesis.juradoManzur, Eugenia
unq.tesis.juradoMuruaga, María Laura
unq.versioninfo:eu-repo/semantics/acceptedVersiones
unq.tipo.snrdinfo:eu-repo/semantics/masterThesises
unq.accesoinfo:eu-repo/semantics/openAccesses
unq.tesis.acta46es
unq.creador.correonoeliayoles02@gmail.comes


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem